telnet my.smtp.server.com 587 Trying XXX.XXX.XXX.XXX... Connected to my.smtp.server.com. Escape character is '^]'. 220 smtp.mandrillapp.com ESMTP ^[^] telnet> quit Connection closed.
To Setup Alerts for CPU and Memory Usage
Anypoint Platform Private Cloud Edition sends alert emails when CPU and memory usage reach a certain threshold:
-
A warning email is sent when CPU and memory usage reach 70% of capacity.
-
A critical email is sent when CPU and memory usage reach 80% of capacity.
Prerequisites
To ensure that alerts work correctly:
-
Verify that your SMTP server can send and receive emails using the addresses you configure as the From and To addresses below.
-
Verify that your cluster nodes are able to communicate with your SMTP server. For example, use
telnet
to connect to your SMTP server from one of your cluster nodes:
Configuring Alerts
-
Configure the FROM and TO email addresses:
-
Login to the Ops Center console, then click Configuration.
-
From the Namespace drop-down, select
kube-system
. -
From the Config maps drop-down, select
alerting-addresses
. -
Select the From tab, then enter the FROM email address used for the alert.
-
Select the To tab, then enter the TO email address used for the alert.
-
-
Configure your SMTP email server. Configuring the SMTP server in Access Manager restarts the Anypoint Platform service responsible for initiating the alerts.